Mains connection

The pressure washer you have acquired is
already fitted with a mains plug. The pres-
sure washer must only be connected to an
earthed socket 230 V ~ 50 Hz.
Only operate the pressure washer
after all the above points have been
observed.
Ensure that the pressure washer is
turned off by its ON/OFF switch (
5).
Insert the mains plug into the mains
socket

Operation

Connect the equipment to the water
tap. Observe the regulations for the
use of a system separator.
Turn on the water tap entirely.
Never operate the pressure washer
with a closed water tap. Dry run-
ning will damage the washer!
Be prepared for the recoil
force of the emitted water jet!
Ensure that you are standing
firmly and that you are hold-
ing the gun (
otherwise you could injure
yourself or other people.
Switch on the pressure washer with the
ON/OFF switch (
Pull the lever of the gun (
on the washer.
Releasing the lever will switch
off the washer, but the pressure
within the system is retained.
A
A
10) securely,
A
5).
A
10) to turn
Lock / unlock the switch-on lever
D
of the gun (10) by depressing
the locking lever (15).
Lock the switch-on lever to prevent
the pressure washer from being in-
advertently/accidentally started.
Locked
Open
In case of leaks in the water
system, immediately switch
off the equipment at the on/
off switch (5) and disconnect
the mains cable (8) of the
equipment from the mains.
There is a risk of electric
shock. Start restoring the wa-
ter connections (see "Initial
Operation – Setting up").
If there is still air in the equipment,
please proceed as follows:
Bleed the supply hose:
1. Remove the quick connection for the
garden hose adapter on the water
connection (9) and open the water tap
until water with no bubbles emerges.
2. Close the water tap.
3. Connect the supply hose to the equip-
ment with the aid of the quick connec-
tion for the garden hose adapter (9).
4. Fully open the water tap.
Bleed the equipment:
5. Switch on the equipment at the on/off
switch (5) until the pressure has built
up.
6. Switch off the equipment at the on/off
switch (5).