GB
MT
• Only use undamaged attachment tools.
• The disc is attached with a keyless chuck
(26) to the uptake spindle (28). There are
two ways to loosen or tighten the keyless
chuck:
• By hand: To do this, fold the bracket
(25) of the keyless chuck upwards.
• With the chuck key (16); kept in the
auxiliary handle (4).
• If you have fitted a cutting disc: Fit the at-
tachment onto the guard cover (seeFitting
and removing the attachment on the
guard cover, p. 36).
Procedure (Fig. C)
1. Check the attachment tool. Do not use
the attachment tool if it is damaged.
2. Press and hold the spindle lock (8).
3. Turn the uptake spindle (28) until the stop
button holds the uptake spindle in a fixed
position. Keep pressing the spindle lock
(8).
4. Loosen the keyless chuck (26).
You can release the spindle lock (8).
5. Disassembly: Take the attachment tool
off the mounting flange (27).
Assembly: Place the attachment tool on
the mounting flange (27).
If a direction of rotation is indicated on
the disc, this must match the direction of
rotation arrow (7)
Ensure that the attachment flange (27) is
placed on the device such a way that the
recesses in the attachment flange grip
into the edge of the device. The uptake
spindle (28) must turn simultaneously
when you turn the attachment flange.
6. Place the keyless chuck (26) on the up-
take spindle (28). The flat side of the key-
less chuck faces the attachment tool.
7. Press and hold the spindle lock (8).
8. Turn the uptake spindle (28) until the stop
button holds the uptake spindle in a fixed
position. Keep pressing the spindle lock
(8).
9. Tighten the keyless chuck (26).
You can release the spindle lock (8).
36
Fitting and removing the wire
brush
Tools required
• Open-end spanner (not included)
Removing the wire brushes (Fig. D)
1. Press and hold the spindle lock (8).
2. Turn the uptake spindle (28) until the stop
3. Release the wire brush with an open-end
Fitting the wire brush (Fig. D)
1. Place the desired wire brush onto the up-
2. Press and hold the spindle lock (8).
3. Turn the wire brush onto the uptake
Fitting and removing the
attachment on the guard cover
.
Requirements
• Cutting disc mounted
• Battery removed from device
Fitting the attachment (17) (Fig. B)
1. Place the attachment (17) on the guard
Removing the attachment (17) (Fig. B)
1. Release one of the two locks (18) on the
2. Slide the released lock (18) over the
CAUTION! Risk of injury when
touching the attachment tool. Wear
protective gloves when handling the
attachment tool.
button holds the uptake spindle in a fixed
position. Keep pressing the spindle lock
(8).
spanner.
You can release the spindle lock (8).
take spindle (28).
spindle (28). Tighten the wire brush using
a combination wrench.
You can release the spindle lock (8).
CAUTION! Risk of injury when
touching the attachment tool. Wear
protective gloves when handling the
attachment tool.
cover (5) and turn the attachment (17) un-
til it audibly clicks into place.
attachment (17) by pushing the lock (18)
outwards.
guard cover (5) until the attachment is re-
moved after half a turn.