17. Troubleshooting
The table below contains a list of error symptoms and explains what you
can do to solve the problem if your tool fails to work properly. If the prob-
lem persists after working through the list, please contact your nearest
service workshop.
Malfunction
The hydraulic
pump does not
start
The column does
not move down
Motor starts but
column does not
move down
Possible cause
No electric power
Thermal switch of
motor cut off
Low oil level
One of the levers not
connected
Dirt in the rails
Wrong turning direction
of 3-phase motor
www.scheppach.com
Remedy
Check cable for electric
power
Engage thermal switch
inside the motor casing
again
Check oil level and refill
Check fixing of lever
Clean the column
Check turning direction
of motor and change
GB | 53