When must the oil be changed?
First oil change after 50 operating hours, then every 500 operating
hours.
Oil change (fig. 12)
• Completely retract the splitting column.
• Put a container with a volume of at least 6 litres under the splitter.
• Release the oil dipstick 14.
• Open the oil drain plug 12a under the oil tank so the oil can fow out.
• Afterwards, close the oil drain plug 12a again.
• Remove the ventilation cap, pour in 3,5 litres of fresh hydraulic oil us-
ing a clean funnel.
• Screw the oil dipstick in again.
Dispose of the used oil in a correct manner at a public collection
facility. It is prohibited to drop old oil on the ground or to mix it
with waste.
We recommend oil from the HLP 32 range.
Splitting spart
Before use, the spar of the splitter must be slightly greased. Repeat this
procedure every five operating hours. Slightly apply grease of oil spray.
The spar may never run dry.
Hydraulic system
The hydraulic unit is a closed system with oil tank, oil pump and control
valve.
The system is complete when the machine is delivered, and may not be
changed or manipulated.
Connections and repairs
Connections and repairs of electrical equipment may only be carried
out by an electrician.
ATTENTION ! Observe the correct direction of rotation when inserting
the saw blade.
GB | 51