17. Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Cause
Automatic oil cut-o trips
Spark plug sooty
No fuel
Engine cannot
Device battery is at
be started
Air lter dirty
Electronics defective.
Power genera-
tor insu cient
Overload protection switch tripped.
or no voltage
Air lter dirty.
Measure
Check oil level, ll with engine oil
Clean or replace spark plug.
Top up with fuel.
If the device's battery is empty, the engine can only be
started using the pull starter.
If the battery is deeply discharged, proceed as de-
scribed in sections 12.2 and 11.4.
Clean or replace the air lter.
Repair by an authorised service centre.
Restart the power generator, reduce consumers.
Clean or replace the air lter.
www.scheppach.com
GB | 39