5.6.
CONTINUITY TEST
Before taking the continuity test, disconnect the circuit under test from any
power source and discharge all capacitors.
1. Perform the preliminary Autotest (see § 4.3).
2. Connect the L1 and L2 probes to the object under test (see Fig. 7)
3.
Continuity test is active for resistance
along with LED "
a continuous sound in case of positive test
4. The instrument automatically turns off when the probes are separated from the object
under test or the applied voltage is lower than 5V DC.
5. Press the
key to switch on the white LED illuminator to perform measurements in
dark environments.
Fig. 7: Continuity test
", the message "Con" is shown on the display and the buzzer emits
EN - 11
CAUTION
<500k. The instrument turns automatically on
HT7