Attention! Be particularly careful when sanding very
thin pieces and extra long pieces (perhaps even with-
out sanding table).
Apply only enough pressure to allow the sanding belt to
remove sanded material.
10.7 Switching the sanding machine on and off (Fig. 1)
• The switch (7) is located on the electrical box.
To switch it on, press "I" (green). To switch off, press
"O" (red).
10.8 Mitre gauge (Fig. 1)
• A mitre gauge (12) for use on the wheel table was
supplied with the sanding machine
• The guide can be used up to 45° to the left or right
by releasing the locking button and setting the mitre
gauge to the desired angle. Then the button is pulled
up again.
10.9 Support plate for the belt (Fig. 14)
• The support plate (j) is a very strong piece of steel that
provides a good support surface during sanding.
• The plate must be adjusted so that it almost touches
the sanding belt. To adjust, loosen the two screws
that hold the plate to the machine frame. Then adjust
the plate and tighten the screws again.
• To remove the plate in order to carry out special
work (e.g. polishing or contour sanding), loosen the
two fixing screws and remove the plate.
10.10 Extraction system (Fig. 15)
• There are two extraction nozzles (10+11) with a di-
ameter of 38 mm that can be easily connected to a
chip extraction system.
11. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
28 | GB
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Ensure that the connection cables are disconnected
from electrical power when checking for damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for machines with a high start-
ing current (from 3000 watts)!
Connection type Y
If the mains connection cable of this device is damaged,
it must be replaced by the manufacturer, their service de-
partment or a similarly qualified person to avoid dangers.
12. Cleaning
Danger!
Pull out the battery before carrying out any cleaning work.
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub the
device clean with a clean cloth or blow it off with com-
pressed air at low pressure.
• We recommend that you clean the device directly af-
ter every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior. Water penetrating an
electric device increases the risk of an electric shock.
www.scheppach.com