The plug coupling must not be actuated/
handled during operation! High risk of injury!
Prior to insertion, check plug coupling connec-
tion of lance for cleanliness (sand, dirt ..) and
use clear water to clean, if necessary. Impuri-
ties may damage the sealing in the plug cou-
pling.
When using high-pressure hose extensions take
care that the max. length of 20 m is not excee-
ded!
Accessories may only be connected to a
STORCH-approved trigger gun with safety
catch.
7. Check water inlet filter for cleanliness prior to put-
ting the high-pressure cleaner into operation. Manually
unscrew plug-in coupling. Take out the water inlet filter
using needle nose pliers and thoroughly rinse it with clear
water and clean it with the other parts. If the sieve is dir-
ty, water can not get through and pressure will not build
up.
Check the water inlet sieve for damage. Do not
operate the high-pressure cleaner without or
with a damaged filter.
8. Connect water hose to water inlet (minimum require-
ments; 5 m hose length, cross-section ¾", 10 bar). The
high-pressure cleaner may be connected to a water mains
(1-10 bar pre-pressure) with either cold or hot water (up to
60 °C).
54
Be careful when using hot water! When running
your high-pressure cleaner with hot water of 60
°C raised temperatures occur. Do not touch the
metal parts of the high-pressure cleaner
without safety gloves!
9. Each time check oil level of the oil sight glass prior to
putting the high-pressure cleaner into operation. Oil level
must be visible in the middle of the oil sight glass.
10. Connect to circuit (see technical data).
Do not touch the mains plug or any live parts
with wet or moist hands.
11. Switch on high-pressure cleaner with opened safety
trigger gun. Bleeding of the high-pressure cleaner: Pull
and release trigger of safety trigger gun several times.
Start cleaning task.
12. Adjust operating pressureinfinitely using the rotary
handle. The maximum pressure is factory-set.
Translation of the original instruction