Care and Maintenance
If the lighting no longer functions, the bulb(s) must be replaced. One/two candle
Replacing the incandescent lamp
bulb(s) is/are required with E14- socket, 220-240 V, max. 40 Watt.
The appliance operates using a hazardous voltage. Before replacing
Electrical shock hazard!
the bulb, disconnect the mains plug. Do not touch any live components
inside the socket.
Before opening the filter flap and removing the bulb, allow the bulb to
Risk of burns!
cool down.
Do not touch the new bulb with your fingers, because this will reduce
Important!
the service life. Use a dry cloth.
1. Disconnect the mains plug or isolate at the appropriate house fuse.
2. Push the lock on the grease filters 1a backwards and remove the grease
filters 1a carefully downwards.
3. Remove the defective incandescent lamp(s) 6 from the socket and install a/
two new one(s).
4. Reinsert the grease filters 1a and close.
5. Reestablish the power supply.
If the glass cover is broken, the extraction hood may not be used
Important!
again until the glass cover has been replaced. Please contact our
Service Team (see "Our service" on page 23).