Camera Setup

Camera Set-Up
Title
Input termination
Camera type
Colour adjust
Contrast adjust
Camera video input
Title
Each camera title can be up to 12 characters long.
Input termination
Termination can be set On or Off. Termination must be off for cameras that are
looped through to other devices.
Camera type
Cameras are detected automatically, to change the camera type choose colour
or mono.
Colour adjust
When the colour bar is selected, press
Note: this option is not displayed if the camera is set as monochrome.
Contrast adjust
When the contrast bar is selected, press down to reduce, and up to increase
the contrast.
Camera video input
This option is only displayed when a camera has failed or is offline. Select
disconnect whilst the camera is offline to prevent the camera fail message and
alarm being triggered.
Tip: This menu can be entered directly by pressing and holding a camera key.
CAMERA 1
On
Off
Colour
Mono
Connected
Disconnected
to reduce, and
to increase the colour.
Alarms and Presets
Alarms and Presets
Camera XX
Telemetry protocol None
>
>
Camera XX
The currently selected camera number is displayed, along with its status – detected
or not detected. Use the camera keys to select a camera to configure alarms
and presets.
Telemetry protocol
Select the telemetry protocol for the camera; BBV, Pelco, DM, JVC*, Ultrak*, or none.
*JVC or Ultrak will only appear if they are selected in the 'System options' menu.
Preset
If the camera has telemetry presets configured, these can be recalled when an
alarm is triggered. Enter the preset number from 00 to 99 for the corresponding
alarm contact. Up to 8 presets can be set for each camera with different alarm
contacts.
Module
Up to 16 alarm modules can be connected to the c-bus network. Each alarm
module is addressed from 01 to 16 - select the address of the alarm module
being used. Details of setting the address can be found in the manual included
with the alarm module.
Contact
Each alarm module has 16 alarm inputs, each input can be used by any camera
or multiple cameras.
Input
Select whether the alarm contact is normally open (N/O) or normally closed (N/C).
Detected
Not Detected
BBV, Pelco, DM, JVC, Ultrak
Preset
Module
Contact
Input
--
01
01
N/O
--
--