Connecting Digital Sprite to a network
Warning: Do not connect Digital Sprite to the network until the network settings
are configured in the menu.
1. Setup the IP address, Subnet mask, and Default gateway using the
'Network settings' option in the 'System options' menu.
2. Restart Digital Sprite.
3. Connect the network to the port labelled 'NET' on the Digital Sprite using the
RJ-45 cable.
Viewing images using a web browser
1. Using a PC connected to the network, open Internet Explorer or Netscape.
2. Enter the IP address of the Digital Sprite in the address box (Internet Explorer)
or location box (Netscape). e.g. 123.456.789.123
3. When the web page is displayed, click on 'Connect' to view live images from
Digital Sprite.
The online manual gives instructions on using the web control panel for live
and playback.
Record Digital Sprite network settings here
IP Address
.
Subnet mask
.
Default gateway
.
.
.
.
.
.
.

Connecting c-bus devices

Digital Sprite uses the c-bus networking system to allow multiple Digital Sprites,
remote keyboards, alarm modules, video switchers, and other accessories to be
connected together. The total length of the c-bus network can be up to 1500m.
Connecting alarms
An optional alarm module is required if alarms are to be added to Digital Sprite.
The advantage of using alarm modules is that all the alarm connectors do not
have to be routed back to the Digital Sprite. Multiple alarm modules can be used
on the c-bus network with alarms connected to each module.
To add alarms:
• Connect the corresponding alarm contact to the alarm input, i.e. Alarm 2
would be connected between ground (GND) and A2.
• If multiple alarm modules are required then each will need to be addressed;
consult the alarm module documentation for details.
• Connect the c-bus cable from the alarm box to one of the c-bus sockets on
Digital Sprite.
• The polarity of the alarms (normally open/closed) is set using the 'Alarms and
Presets' menu page.
A1
A2
A3 A4
GND
An alarm trigger performs the following
Action
Close/Open relay 1
Automatically copy the alarm camera to Zip® or Jaz®
Display the alarm camera on screen
Change the record rate
Record exclusively or interleave the alarm cameras
Menu page
Alarm Setup
Alarm Setup
Alarm Setup
Record Schedule
Record Schedule
9