2.2 USING THE TOOL MANAGER SOFTWARE
2.2.12 DISPLAYING AND SAVING THE HISTORY LOG
• Double-clicking the row of a history log displayed on the history display screen will open
the history detail window and display the graph data of that history log.
• The graph to display can be changed by using the [<] [>] buttons and pull-down menu
(①) above the window. Change history log folders of the selected tool by using [<] and
[>], and select a history log to display the graph for from the pull-down menu.
• By selecting pull-down menus (②) under the graph, you can set tightening torque,
tightening angle, or speed as a vertical axis of the graph, and set tightening work time,
tightening angle, or number of pulses as a horizontal axis.
• By selecting a pull-down menu (③) under the graph, you can change the scale of the
graph.
• The data window (④) in the right displays the log data for each sample (every 20 ms in
no-load fastening, and every one pulse in pulsing) in one tightening job.
• You can expand the window by dragging the end of the history detail window.