Herunterladen Diese Seite drucken

Panasonic EYFMH1WC Bedienungsanleitung Seite 61

Kabelloser elektro-mechanischer schlagschrauber

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Angle Error Shut-Off
[Functional overview]
With this function ON, if the set upper-limit angle is exceeded during tightening work,
the tool will stop operating automatically.
To use this function, you need to set the upper-limit angle.
[Default value]
OFF
[Setting value]
ON, OFF
No Load Speed
[Functional overview]
Set the anvil rotation speed from trigger-on to tool pulsing start in 100 rpm steps.
[Default value]
2300 rpm
[Setting value]
1500 rpm to 2300 rpm
Variable Speed Control
[Functional overview]
When this function is ON, the no-load speed changes according to the trigger pull-in
depth.
If this function is OFF, the no-load speed will be fixed at the set rpm.
[Default value]
OFF
[Setting value]
ON, OFF
Storage Option When Limit Reached
[Functional overview]
This option allows you to select whether to automatically update history logs or prohibit
tool operation when the history log storage space in the tool has reached the limit.
[Default value]
Auto Delete
[Setting value]
Auto Delete, Fastening Prohibited
Entering the value with (*) will disable the function.
EN
- 61 -

Werbung

loading

Diese Anleitung auch für:

Eyfmh2wcEyfmh1wpEyfmh2wp