Technical Data

Safety

TP 1500, TP 1500
Mains voltage
VRD, TP 1500 RC,
Mains fuse slow
TP 1500 TIG, TP
1500 TIG VRD
Cos phi (140 A)
Efficiency (at 80 A)
Welding current range
Welding current at
Apparent power at
Open-circuit voltage
Standardised operating voltage
Degree of protection
Type of cooling
Insulation category
Approval marks
*d.c.: duty cycle
Note! Inadequately dimensioned electrical installations can lead to serious
damage. The mains supply lead, and its fuse protection, must be dimensioned
accordingly. The technical data shown below on the rating plate shall apply.
Electrode - DC
TIG - DC
10 min/40°C (104°F) 25% d.c.*
10 min/40°C (104°F) 35% d.c.*
10 min/40°C (104°F) 60% d.c.*
10 min/40°C (104°F) 100% d.c.*
35% d.c.*
60% d.c.*
100% d.c.*
Standard version
50V version
TP 1500 VRD, TP 1500 TIG VRD
Electrode
TIG
2 1
230 V
16 A
0.99
86.8 %
10 - 140 A
10 - 150 A
150 A
140 A
100 A
80 A
6.9 kVA
4.8 kVA
3.6 kVA
92 V
50 V
12 V
20.4 - 25.6 V
10.4 - 16 V
IP 23
AF
B
S, CE