ATTENTION! Danger of burning! Wait until the device has cooled
down before performing cleaning or maintenance work.
10.1 Cleaning
Keep protective devices, air vents and the motor housing as free of dust
and dirt as possible. Rub the device clean with a clean cloth or blow it
off with compressed air at low pressure. We recommend that you clean
the device directly after every use.
Clean the device at regular intervals using a damp cloth and a little soft
soap. Do not use any cleaning products or solvents; they could attack
the plastic parts of the device. Make sure that no water can penetrate
the device interior.
10.2
Maintenance
WARNING!
Always wear protective gloves and a mask during maintenance work!
10.2.1 Checking the oil level
1. Proceed as described in 8.2.
10.2.2 Changing oil (Fig. 7 + 8)
Change the engine oil after 20 operating hours, then after 50 hours or
every three months.
The engine oil change should be carried out while the engine is at oper-
ating temperature.
1. Place the power generator on a level, even surface.
2. Remove the engine cover (3) as described in 8.2. (Fig. 7)
3. Provide a collection container (not included in the scope of delivery).
4. Open the oil dipstick (20) and drain warm engine oil into the collec-
tion container by tilting the power generator.
5. Fill up with new engine oil (approx. 0.35 l).
6. Screw the oil dipstick (20) in again.
7. Dispose of the used oil properly.
GB | 61