St2 | E 14
Cause:
Remedy:
St2 | E 15
Cause:
Remedy:
St2 | E 16
Cause:
Remedy:
26
At maximum wire feed speed, the motor current of the wire-feed unit
motor is outside the permitted range. Possible reasons are disenga-
ged wire-feed unit motors or wire feed problems.
Engage the drive units of both wire-feed unit motors, arrange the ho-
sepack in as straight a line as possible; check the inner liner for kinks
or soiling; check the contact pressure on the 2-roller or 4-roller drive
of the push-pull unit. Repeat the push-pull calibration. If the error
message re-appears: Contact After-Sales Service
At maximum wire feed speed, the motor current of the push-pull unit
is outside the permitted range. Possible reasons are disengaged wire-
feed unit motors or wire feed problems.
Engage the drive units of both wire-feed unit motors, arrange the ho-
sepack in as straight a line as possible; check the inner liner for kinks
or soiling; check the contact pressure on the 2-roller or 4-roller drive
of the push-pull unit. Repeat the push-pull calibration. If the error
message re-appears: Contact After-Sales Service.
Push-pull calibration was interrupted: Quick-stop was activated by
pressing the torch trigger.
Repeat push-pull calibration