Herunterladen Diese Seite drucken

Dibo HOTBOX-GK 50/10 Originalbetriebsanleitung Seite 90

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

E N
    S E R V I C E
DESCRIPTION DAILY CONTROL
1
Frame
Check the frame in its entirety at loose bolts and/or cracks of the welds. Keep
the machine as much as possible clean to prevent act on dirt, water, oil and
messed fuel
2
Valves + manometer
At a switched off machine, this means a halted engine, the manometer must
reflect 0 bar. At a maximum performing machine, this means operated at full
load working engine, the manometer can not indicate more than the maximum
pressure by DiBO indicated, for your machine. After operation and releasing
the spray gun, there still can remain a small pressure remainder present in the
conduits. The reflected value of the manometer must be between 0-30 bar, the
valves are then all right.
3
High- and low pressure parts
Check the hoses, piping and connections on external damages and leaks.
If damaged or if there are leaks, these must be replaced immediately.
4
Electrical part
Checks visible electric wiring and components (among other things: switches)
on external visible damages. If damaged, replace the concerning parts
immediately.
5
Burner
Check if the burner opening is clear of pollution. Check pipes and connections
on leaks and external damages. Replace the filter if necessary.
Ignition transformer from the burner:
It is important that on the ignition transformer a load is connected.
The switching on of the ignition transformer without the ignition pins are
connected, are not permitted. We recommend during maintenance activities
certainly checking the connections of the ignition cables and for the case the
burner would not work, certainly don't run the burner.
6
General control of the tanks
Check all tanks on external damages and leaks. Check at filling of the water
tank if the float system works properly.
7
Softener tank
Regularly clean the vent cap, remove product residues!
DiBO 26