7.4
Cleaning the filter
8 Hose connection
9 Filter seal
1. Unscrew hose connection 8
2. Remove, clean and reinsert filter seal 9
3. Mount hose connection 8
7.5
Electrical connection of the pump
with terminal clamps
Connect the 4 m-long connection cable to a suit-
able DC power source with terminal clamps:
Red:
positive terminal
Black:
negative terminal (-)
i
Important:
In the black holder on the connection
cable there is a blade fuse compliant with
DIN 72581/3C.
: Blade fuse as required by DIN 72581/3C
; Red terminal clamp (+)
< Black terminal clamp (-)
(+)
8
Additional tank COMBI 440/50
With electric pump and delivery nozzle for urea
solution AUS 32.
8.1
Layout
15
B Ventilation valve
C Filling opening
P AdBlue delivery nozzle
8.2
Technical data
8.2.1
Additional tank for AUS 32
Dimensions L x W x H mm:
Nominal volume:
8.2.2
Pump 12 V
Voltage:
Fuse:
Power:
Delivery rate:
max. delivery pressure:
Liquid temperature:
1
2
638 x 421 x 561
50 l
12 VDC
25 A (at the pole terminal)
220 W
approx. 25 l/min
1.1 bar
-5 °C to +40 °C