Herunterladen Diese Seite drucken

Parkside PTBM 550 A1 Originalbetriebsanleitung Seite 26

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
GB
MT
c) Do not wear gloves. Gloves can
be caught by rotating parts or drilling
chips and thus cause injuries.
d) Keep your hands away from the
drilling area while the power
tool is running. Contact with rotating
parts or drilling chips can lead to inju-
ries.
e) The drilling tool must rotate
before you guide it to the work-
piece. Otherwise the drilling tool can
get caught in the workpiece, causing
unexpected movement of the workpiece
and injuries.
f) If the drilling tool jams, stop
pressing down and switch off
the power tool. Investigate and
eliminate the cause of the blo-
ckage. Blocking can lead to unexpec-
ted movement of the workpiece and to
injuries.
g) Avoid long drilling chips by re-
gularly interrupting the down-
ward pressure. Sharp metal chips
can get caught and cause injuries.
h) Never remove drilling chips
from the drilling area while the
power tool is running. To re-
move chips, move the drilling
tool away from the workpiece,
switch off the power tool and
wait for the drilling tool to stop.
Use tools such as a brush or
hook to remove the chips. Contact
with rotating parts or drilling chips can
lead to injuries.
i) The permissible speed of insert
tools with rated speed must be
at least as high as the maximum
speed indicated on the power
tool.Accessories that run faster than
the permissible speed can break and fly
apart.
26
Safety Instructions for
Handling the Laser
– Caution: Laser radiation - Do not look into
the beam - Laser class 2
– Do not aim the laser at reflective surfaces.
– Markings and warnings are located next
to the hand spindle guide (16).
Additional Safety
Instructions
• If replacement of the connecting cable
is required, this must be carried out by
the manufacturer or his representative
in order to avoid safety hazards.
• Overhanging workpieces may have to
be laterally supported by additional
supports.
Assembly
The bench drill is supplied disassembled.
Clean the column tube (3), baseplate (6),
drilling bench (8) and the drill chuck (12)
beforehand, with a dry cloth.
1. Place the column tube (3) on the base-
plate (6).
Make sure that the three drill holes on
the baseplate (6) and the base of the
column tube (3) line up.
2. Bolt the column tube (3) to the base-
plate (6) with the three supplied assem-
bly screws (5). Tighten the assembly
screws (5) moderately tight so that the
threads in the baseplate (6) do not
strip.
3. Place the drilling bench (8) on the
column tube (3). Push the drilling
bench (8) into a lower position. Fix the
drilling bench (8) in a lower position
with the tommy screw (4).
Loosen the tommy screw (4) a bit if the

Werbung

loading