Maintenance
As the viscosity of hydraulic fluids changes considerably through fluctuations in temperature,
compromises cannot be avoided in their selection. For your PALFINGER crane the following limit
values apply:
• High temperatur range:
• Cold start limit:
• Purity class:
Owing to different basic products different service temperatures apply:
• Fluids based on mineral oil:
• Biodegradable fluids:
The ideal operating temperature of the hydraulic fluid is between 30°C and 60°C
10 cSt
1000 cSt
15/12 (nach ISO 4406)
Fully synthetic ester:
Native ester:
Fluids based on rape oil:
6.1-5
approx. -30 bis +80°C
approx. -30 bis +80°C
approx. -20 bis +80°C
approx. -20 bis.+65°C