6.1-4
6.1-4
Lubrication
The following maintenance and care instructions apply to all Palfinger cranes. In this Chapter you
will therefore find instructions which do not relate to your crane
Inadequate or incorrect lubrication leads to increased wear and therefore to unnecessary repairs
(idle time) to the crane. Therefore always ensure that bearings, hydraulic extendable arms,
mechanical extensions and outriggers are always sufficiently lubricated and that only lubricants are
used which correspond to the specification included below.
Lubricant to be used:
Only solid-free greases without graphite, MoS2, etc. may be used for
lubrication. The use of other greases will quickly lead to damage to
the bearings on the crane.
Bearings:
Structure
Consistency (NLGI)
Code
Dripping point °C
Walk penetration
Oxidation resistance 100 h / 100 °C
Basic oil viscosity at 40°
Behaviour in contact with water
Extendable arms, mechanical extensions, Outrigger etc.:
Structure
Soap basis
Consistency (NLGI)
Code
Dripping point °C
Walk penetration
Oxidation resistance 100 h / 100 °C
Basic oil viscosity at 40°
Behaviour in contact with water
Technical Data
Technical Data
Maintenance
tested to:
smooth
2
DIN 51818
KP2K-35
DIN 51502
150
DIN ISO 2176
265/295 1/10mm
DIN ISO 2137
max. 0.2 bar
DIN 51808
80mm²/s
>
Waterresistant
DIN 51807-1
tested to:
smooth
Ca complex
2
DIN 51818
KP2K-35
DIN 51502
150
DIN ISO 2176
265/295 1/10mm
DIN ISO 2137
max. 0.2 bar
DIN 51808
>80mm²/s
Waterresistant
DIN 51807-1