The Meaning Of The Leds - Aerex Reco-Boxx Rb 600 Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Reco-Boxx RB 600:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Ventilation level Function
Ventilation
Reduced ventilation:
level 1 /
LED 1 lights up, the
Continuous
ventilation unit runs at
operation
ventilation level 1.
Ventilation
Nominal ventilation:
level 2
LED 2 lights up, the
ventilation unit runs at
ventilation level 2.
Ventilation
Intensive ventilation:
level 3
LED 3 lights up, the
ventilation unit runs for
approx. 1 hour at
ventilation level 3. After
that, the ventilation unit
switches back to
ventilation level 2.
The switch-back function
can be deactivated by a
specialist installer
(jumper 7 has to be
bridged on the control
circuit board, see
Chapter 9.6.3).
The volumetric flows can be adjusted
i
separately for each ventilation level,
both for the exhaust air and the
supply air. The settings are done by
your specialist installer.

5.2.5 The meaning of the LEDs

LED
Meaning
All LEDs off
Ventilation unit in
standby mode.
LED 1, 2 or 3
Display
lights
Reduced ventilation,
permanently
nominal ventilation or
intensive ventilation.
LED 1 flashes
Interval operation /
regularly at
Frost protection
short intervals.
ventilation
LED
Meaning
The selected
Carry out a filter
ventilation level
change. 3-month filter
LED flashes
change period has
regularly at
elapsed.
longer intervals
 Change the air filter as
 Then, press both the
All 3 LEDs flash quickly
for a short time. The filter
change period counter is
reset to 0.
All 3 LEDs flash
Fault:
● Supply air temperature
regularly at
longer intervals
dropped below frost
protection temperature
(only if TH 10
connected)
● Fan failure.
●Temperature sensor
faulty.
Resetting the error
message:
 Press the plus but-
The flashing LED is
switched off.
 Call on the services of
In the case of a filter change before
i
the filter change period has
expired:
Press both the ▲ and ▼ buttons at
the same time for about 10 seconds.
See Chapter 7.3 for faults and their
i
rectification.
described in Chapter
6.2.
▲ and ▼ buttons
at the same time for
about 2 seconds.
ton ▲ for approx.
5 seconds.
a trained electrician if
the LED continues to
flash or if the fault
recurs.