CUSTOM INSTALLATION (C.I.) USE
The 540R V2.0 features a Control Bus input that allows un-modulated
remote control commands (positive logic, TTL level) to be received
electrically by the unit. These control commands are typically generated
by custom installation (multi-room) systems or remote IR receiver
systems. The Control Bus socket is colour-coded orange.
This unit features 'direct' IR/Control codes as well as toggle codes for
many of their features to simplify programming custom installation
systems. Special direct On/Off commands can be accessed on the
supplied remote control for teaching into C.I. systems as follows:
1. Press and hold the Standby/On button on the remote control. The
remote first generates it's standby (toggle) command. Keep the
button held down, after 12 seconds an AV receiver "On" command
will be generated. If the button is kept held down for a further 12
seconds, an AV receiver "Off" command is generated.
Repeat this procedure with the Mute, Sub On/Off, Stereo Mono and
Tuner AM/FM buttons to send On/Off commands. The Tuner AM/FM
button also provides unique FM and AM commands to allow switching to
a specific band.
A full code table for this product is available on the Cambridge Audio
website at www.cambridge-a a udio.com.
28 Azur AV receiver
RESET/BACK-UP MEMORY
The 540R V2.0 has a function that preserves the preset memory and
other settings. In the event of a power failure, or if the power cord of the
unit is disconnected from the mains outlet, the back-up memory will
preserve the preset memory for approximately one week. If the power
supply is interrupted for 7 days or longer, the memory settings will be
erased.
If it is desired to reset all settings to their factory defaults or in the
unlikely event that the unit locks up due to an electrical discharge etc,
switch the Power to On on the rear panel, and using a paper clip (see
diagram below), press and hold the Reset button for three seconds.
"RESET" will appear briefly on the front panel display before returning to
Standby mode.
Component Video Out
www.cambridge-audio.com
Reset
r/Pr
Cb/Pb
Y
Left
Power AC
Designed in London, England
On
Power
Off