Herunterladen Diese Seite drucken

ATH-Heinl Four Lift 64AP Bedienungsanleitung Seite 93

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Note
The corresponding
operating instructions.
1
2
T-piece supply line
2.10.2.4
Installation and connection of the electric control
Attach the electric control to the front left column
Lead all cables through the glands into the control box and connect them there according to
diagram".
2.10.2.5
Adjustment work before fixing the lifting platform
Check all screws, nuts, etc. for tightness
Check all connections and cylinders for tightness and retighten if necessary
Attention
Do NOT operate the pump-motor unit without oil.
Otherwise, damage to the pump may occur. If the motor becomes hot or makes strange
noises, stop immediately and recheck the electrical connection.
Observe the direction of rotation of the motor. When the LIFT button is pressed, the motor fan wheel must
rotate in the direction indicated. The unit must start to pump oil after approx. 15 seconds. If not, the direction
of rotation must be changed.
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
"Pneumatic circuit diagram"
Release date: 02.06.2023 / Product manufacturer ATH-Heinl GmbH & Co. KG
can be found in the appendix to these
Pneumatic valve
"Electrical circuit
93