Technical data
Type
Load capacity
Time for lifting (2000 kg)
Time for lowering (2000 kg)
Electrical system
Control voltage
Motor
Upstream fuse
Connection cable
Protection class
Working pressure
2
Recommended hydraulic oil
Oil quantity
Ground anchoring
Anchor quantity
Recommended air pressure
Permissible sound value
Weight
Warning
The factory-set working pressure is adjusted to the maximum nominal load. The pressure
2
relief valve must not be tampered with.
Changing the setting can lead to serious damage.
Note
If the specified nominal load cannot be raised, please contact our service team.
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
76
ATH Four Lift 64AP
6400 kg
45 s
42 s
3/400V/50Hz
DC 24 V
3 KW
3 C 16 A
Min. 5 x 2,5m
IP 43
Approx. 190 bar
Summer (10° to 45°): HVLP-D 46 (e.g.: Eni PRECIS HVLP-D)
Winter (below 10°): HVLP-D 32 (e.g.: Eni PRECIS HVLP-D)
Approx. 18 l
Bolt anchor: M16 x 180 (e.g.: Atrion ABL-W 16-060-180)
Composite anchor: M16 x 190 (e.g.: Atrion AVA-W 16-045-190)
16 pieces
8 bar
≤ 76 dB
2850 kg