The machine must be fastened at the intended points with suitable fastening material, if specified.
When selecting the installation site, the guidelines and instructions of the accident prevention regulations and
the workplace regulations must be observed in addition to the ground conditions.
When installing on floor ceilings, their sufficient load-bearing capacity must be checked. In general, it is
recommended that a building expert be consulted for an assessment when installing the device on floor ceilings.
2.7
Electrical connection
Attention
The general as well as the local regulations must be observed. Therefore, this step may only
be carried out by a trained specialist.
Pay attention to the necessary supply line.
Voltage deviations should not exceed 0.9 - 1.1 times the nominal voltage range and frequency deviations should
not exceed 0.99 - 1.01 times the frequency range. To be able to guarantee this, necessary protective measures
must be taken.
At the end of the work, the direction of rotation of the motor must be checked.
2.8
Pneumatic connection
Attention
For all pneumatic systems, a compressed air maintenance unit (sometimes included in the
scope of delivery) must be installed between the supply line and the system.
The air pressure of the supply line must at least correspond to the
The correct setting of the compressed air maintenance unit must be checked.
The compressed air maintenance unit must be serviced at regular intervals.
The maximum or minimum pressure ensures proper function without possible damage.
2.9
Hydraulic connection
Note
Before the system is put into operation or is operated with oil for the first time, the following
must be observed with regard to the optimal, trouble-free as well as almost air-free function.
All hydraulic lines must be connected and tightened according to the hydraulic plan or hose designation.
All hydraulic lines and cylinders must be vented according to the hydraulic plan or hose designation.
In order to ensure the proper and safe functioning of the system and the hose lines used, it is essential to ensure
that the hydraulic fluids used comply with the specific specifications and recommendations of the manufacturer.
® Copyright ATH-Heinl GmbH & Co. KG / All rights reserved / Misprints and technical changes reserved
84
Release date: 02.06.2023 / Product manufacturer ATH-Heinl GmbH & Co. KG
"Technical
data".