Herunterladen Inhalt Inhalt Diese Seite drucken

Special Accessories - Bosch FSA 740 Originalbetriebsanleitung

Fahrzeug-system-analyse
Vorschau ausblenden Andere Handbücher für FSA 740:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
3.3.2
FSA 740 rear view
1
6
5
11-16V
4597758/3Wo
Fig. 2:
FSA 740 rear view without rear wall
1 Measuring unit
2 PC
3 Printer (PDR 377)
4 BEA 055
*)
5 ON / OFF switch with socket strip
6 KTS modul
1)
sometimes provided as special accessory
1)
3.3.3
Measurement lead with voltage divider
The measurement lead with voltage divider
(1 687 224 300) is used for voltage measurements up
to 60 VDC/30 VAC/300 VACpeak. The accessory set
(1 687 016 118) contains test prods (1 684 485 434/
... 435) and pick‑off clips (1 684 480 403/ ... 404) as
accessories for the measurement lead with voltage
divider. Never use the measurement lead with voltage
divider to measure mains or similar voltages.
Robert Bosch GmbH
GF 3
GF 2
O2
AF I
4
N0
Product description | FSA 740 | 21
3.3.4
FSA 740 terminal strip
DANGER – Risk of electric shock from ex-
cessively high measurement voltage.
The measurement of voltages in excess of
60 VDC/30 VAC/42 VACpeak using Multi
measurement leads CH1 / CH2 will result in
injury, heart failure or fatal electric shocks.
Never use Multi measurement leads CH1 /
CH2 to measure mains or similar voltages.
COM
15+
- 1
2
1
2
3
4
Fig. 3:
FSA 740 terminal strip (from below)
1 Temperature sensor
2 Connecting cable B+/B–
3 Primary connecting cable (UNI 4)
4 Trigger clamp or
adapter line 1 684 465 513 for clip-on sensor
3
5 RS 232 serial interface (no function)
6 Sensor KV–
7 USB connection for data connection PC
8 Sensor KV+
9 Power supply for measuring unit (power pack)
10 Multi measurement lead CH1 or measurement lead with voltage
divider or current probe 30 A
11 Multi measurement lead CH2 or measurement lead with voltage
divider or current probe 30 A or current probe 1000 A
12 Stroboscope
13 Air pressure measurement
14 Liquid pressure sensor
When the speed is being measured with the clip-on sensor,
1)
adapter line 1 684 465 513 must always be connected between
plug socket FSA 740 and the connecting cables for the clip-on
sensor.
3.4

Special accessories

Information on special accessories, such as vehicle‑
specific connecting leads, can be obtained from your
authorized Bosch dealer.
D
X
KV-
KV+
CH1
CH2
USB
15V DC
5 6 7 8 9 10 11 12 13 14
1)
1 689 979 895
|
en
45977541-Ko
2014-10-28

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis