1.
Refer to the steps below, you can enable the Table on (
a)
Long press the Menu button until you see
b)
Release the Menu button and
c)
Short press the No button several times until
d)
Press the Yes button to enter the sub menu.
e)
Short press the No button several times until
button to enter the table setting options.
f)
Short press the No button until
g)
Press the Yes button to confirm.
Press the Exit button to exit.
h)
2.
When the Table option is enabled.
In automatic totalization mode, the scale will automatically totalize the current weight when it performs
totalization successfully.
In manual totalization mode, you can press the Function button to totalize the current weight and
print it accordingly.
3.
The output for current weight will appear as the example below.
Example:
1.
1000 g N
2.
2000 g N
3.
3000 g N
4.
1999 g N
5.
1000 g N
-------------------------
4.
When the totalization is finished, you can print the totalization result by below steps.
1.
Remove the load from the scale.
Press the Function button, and the totalization result appears on the display.
2.
3.
Press the Print button to print the result.
Refer to the example below, you will see the output of the totalization result.
Example:
-------------------------
n:
Total:
100.000 g
Avg:
200.000 g
Min:
10.500 g
Max:
88.200 g
Diff:
78.300 g
NOTE: The scale supports 32 characters, the first line is "-". The colon is left aligned, and the
Weights/Numbers are right aligned.

3.5.3 Dynamic Weighing / Display Hold

This application is used to weigh an unstable load, such as a moving animal. Three different start/reset
operation types can be selected:
OFF
Off (
)
mMAN
Manual (
)
SEmMI
Semi-Automatic (
AUtO
Automatic (
)
Display Hold
The C52 is set to Display Hold as a default. The instrument will hold the displayed weight value on the display if
that weight is greater than 5 divisions.
NOTE: The minimum start weight is 5 divisions. If the scale does not operate properly, please check if the load
is greater than 5 divisions.
C.A.L
. appears on the display if CAL lock is off.
On
appears on the screen.
5
= Disable the mode.
= Averaging and resetting are initiated manually by pressing the FUNCTION key.
= Averaging is automatically initiated when the load weight is bigger than the start
)
weight; resetting is initiated by pressing the FUNCTION key.
= Averaging is automatically initiated when the load weight is bigger than the start
weight; resetting is automatically initiated when the weight on the display is less
than 5d.