3.5.2 Totalization

This application is used to accumulate multiple weights manually or automatically. Statistical data (the number
of samples, the total weight, the average weight, the minimum weight, the maximum weight and the difference
in weight) is stored in memory for review and printing.
Application Settings
There are three totalization options:
OFF
Off (
):
mMAN
Manual (
):
AUtO
Automatic (
):
NOTE: Manual is the default setting.
Selecting the Totalization Options:
Long press the Menu button until the
1.
2.
Release the Menu button, the
Short press the No button several times until
3.
button. If you do it successfully, you can see the
Short press the No button several times until
4.
the sub menu.
5.
Short press the No button several times to select the desired totalization option. If the desired option
appears on the display, you can press Yes button to confirm.
6.
Press the Exit button to exit.
Starting the Totalization Process
1.
Long press the Mode button until
2.
Release the Mode button, and the
3.
Refer to the explanations below to determine whether to press Yes or No button.
To delete the stored totalization result of the last time for a new round of the totalization process, you
can press the Yes button. The display shows
To reuse the stored totalization result of the last time, you can press the No button to continue the
totalization of the last time. The display shows
If there is a container on the scale, the display shows
press the Tare button to tare.
4.
Put the object on the platform and wait for the
NOTE: Please make sure that the object weight is greater than 5d.
5.
Remove the object from the platform.
6.
Put the next object on the platform and wait for the
7.
Steps 5 and 6, if you have more than two objects that need to be weighed.
8.
Remove all the objects from the platform.
9.
Press Function button to check the result.
NOTE:
The gross and net weight cannot be added to the same total. If the first weight is recorded in gross, the
next one should be recorded in the same way. It is the same for the net weight.
The result includes the number of samples, the total weight, the average weight, the minimum weight, the
maximum weight, and the difference in weight (the maximum weight minus the minimum weight). The
values are displayed for 1 second each.
Totalization Rules
You will fail to do the totalization operation under the following conditions.
1.
The current weight value is unstable.
2.
The net weight of the load is smaller than 5d.
3.
The overall totalized weight is larger than 999999.(The unit depends on your setting.)
4.
The total number of totalizations exceeds 9999 times.
Disable the totalization function.
Enable the totalization function manually with Function button.
`
The scale performs the totalization function automatically.
mM.E.N.U
C.A.L
appears on the display.
tOtAL
appears on the display.
CL.ACC
appears on the display.
mM.O.d.E
appears on the display, then press the Yes
reset
on the display.
t0tal
appears on the display, then press Yes button to enter
appears on the display.
0.000
.
0.000
.
CL.PAN
until the container is removed or you can
"
"
flashes on the display.
"
"
flashes on the display.