Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions; Troubleshooting; Maintenance - Ferm HBM1001 Gebrauchsanweisung

Richt- /und ausbeulwerkzeug satz
Inhaltsverzeichnis

Werbung

EXPLODED VIEW HB-4
SPARE PARTS FOR HB-4
POSITION
DESCRIPTION
2
495 MM EXTENSION BAR
3
418 MM EXTENSION BAR
4
215 MM EXTENSION BAR
5
125 MM EXTENSION BAR
6
82 MM EXTENSION BAR
7
SERRATED CAP, 1/2 TON
8
SPREADING WEDGE
9
RUBBER HEAD
10
BASE PLATE
11
RAM TOE
12
PLUNGER TOE
13
CLEFT CAP
14
"V" BASE
15
HOLE CON NECTOR
16
4 TON PUMP UNIT
17
RAM UNIT
18
HYDRAULIC HOSE
-
HOSE/UNIT CONNECTION BOLT
-
NUT FOR CONNECTION BOLT
-
REPAIR KIT
38
HYDRAULIC BODY REPAIR SET
THE NUMBERS IN THE FOLLOWING TEXT
CORRESPOND WITH THE PICTURES AT PAGE 2

SAFETY INSTRUCTIONS

The following pictograms are used in these instructions
for use:
In accordance with essential applicable safety
standards of European directives
Denotes risk of personal injury, loss of life or
damage to the tool in case of non-observance of
the instructions in this manual.
Danger - Keep hands away from moving parts
Carefully read this manual before using the machine.
Make sure that you know how the machine functions
and how to operate it. Maintain the machine in
accordance with the instructions to make sure it
functions properly. Keep this manual and the enclosed
documentation with the machine.
ADDITIONAL SAFETY INSTRUCTIONS
Fig.6
A. Never exceed the maximum load capacity of the
ram. Do not over extend the ram, as it is possible to
NO
force the plunger out of the top of the ram.
B. When coupler valves are disconnected always insert
104059
the dust cap to keep the oil lines clean.
104061
C. If the load is not centered to the ram plunger, pump
104062
carefully. If you have to use excessive pressure to
pump the ram, stop the operation and adjust the set-
104063
up so that the load is more central. This should
104064
decrease the effort required.
D. Do not drop any heavy objects onto the hose, and do
104069
not allow the hose to kink. Always allow clearance
104058
for the hose to avoid damage to the hose and
104070
couplers.
E. Keep the equipment away from heat or fire, as this
104060
may damage or weaken the equipment.
104071
104072
USE
104073
ATTACHMENT COMBINATIONS
104074
Fig.1 - 5
104075
The pump unit can be used with the multi-directional
ram. (see Fig.1)
104056
For confined areas the hydraulic spreading wedge
104057
should be used. (see Fig.2)
104067
Fig.3 shows a few of the many attachment
combinations.
104065
104066
104068
Ferm
Ferm
1. Connect the hydraulic ram and pump unit hose
together, ensure you have securely fastened the
couplings before pumping.
2. Firmly close the releast valve by turning it in a
clockwise direction (See Fig .4, A).
3. Apply pressure to the pump by pumping the handle
up and down.
4. To release the pressure turn the valve anti-clockwise
(See Fig .4,B).
The pump can be used in any position, but always
keep the hose end of the pump unit facing
downwards when positioned vertically (See Fig .5).
TROUBLE SHOOTING
1. Pump unit will not work
Dirt on valve seals/Worn seals.
Replace with new seals.
2. Pump unit will not produce pressure
Air block
Open the release valve and remove oil filler plug.
The reservoir could be overfilled or low on hydraulic
oil level.
To check the oil level, remove the filler plug. Top up oil
to correct level.
3. Pump unit feels unsteady under load
Air block.
Pump handle a couple of full strokes and close the
release valve.
The pump cup seal could be worn out.
Replace the cup seal with a new one.
4. Pump unit will not lower completely
Air block
Replace filler plug
Release air by removing filler plug.

MAINTENANCE

When the body repair kit is not in use, the pump
unit should be stored with the release valve open.
REFILL OIL
Fig.7
To check the oil level, place the pump unit in an upright
position, as indicated on the diagram. If required add
hydraulic oil until it is level with the full mark.
Remove the dip stick and the oil level will be
indicated.
Your jack was filled at the factory with high grade
hydraulic oil. Only use approved oil.
After extensive use, the oil supply should be replaced
to ensure longer equipment life. To drain, remove
the dip stick and open release valve. Ensure that no
dirt gets into the system. Refill with approved oil.