Herunterladen Inhalt Inhalt Diese Seite drucken

Parameter Description; Lc-Display Mode - Siko MA508 Montageanleitung

Vorschau ausblenden Andere Handbücher für MA508:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MA508
32

Parameter Description

Summary of the "PowerOn" default values
Parameter

LC-Display mode

resolution
decimal point
counting direction positive
reset delay
7 Parameter Description
Below, all parameters and functions of the electronic display are
explained. The column "Menu text PTM" showns the allocated text dis-
play. For this purpose, the operating mode "PCon" is selected in the PTM
(see User information "PTM").
7.1 LC-Display Mode
Description
The user wakes the LC display by pressing the
The LC display is automatically switched off after the
next actuation of the
inactivity.
LCD
On
LC-Display
LC-Display On
The LC display appears with sensor movements* or by
pressing the
key. The LC display is automatically
switched off after the next actuation of the
after 15 minutes of inactivity.
LCD
On with movement or
LC-Display On
LC-Display
LC display is olways on. The
* The condition sensor movement is met as soon, as the sensor was moved
by at least 2.5 mm and no "ERROR" status exists (see chapter 5.4).
Accordingly, there is inactivity when the sensor has not been moved by
2.5 mm within ~15 min. The LC display will then be switched off.
MA508 · Date 23.05.2017 · Art. No. 83093 · Mod. status 304/16
Value
display always on
0.1 mm
0.0
off
key of after 15 minutes of
Off
or switch off after
15 min.
Off
key
or switch off after
15 min.
key has no effect.
English
Menu text PTM
"Lc.tA"
key.
"Lc.SE"
key or
"Lc.On"

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis