Installation
NOTICE
NOTICE
Loss of measured values
` The tolerance and gap measures shall be observed over the whole
measuring length.
1. Mount magnetic tape (see chapter 4.3).
2. Fasten the magnetic sensor on a level work surface through the thru-
holes (2x ø3.5 mm) (for the fastening dimensions refer to the Data
Sheet). We recommend to use the enclosed fixing screws and washer
springs (fastening torque 0.25 Nm).
2
3
<1°
5
7
Fig. 7: Definition of the counting direction with magnetic tape and
assemblage sensor / magnetic tape, gap measure, tolerances

4.5 Mounting an integrated magnetic sensor with magnetic tape

Alignment of the magnetic sensor
` Take care that the electronic display with integrated magnetic sensor
is aligned correctly in order to ensure optimum sensing (see
MA508 · Date 23.05.2017 · Art. No. 83093 · Mod. status 304/16
1
4
<3°
Active side of the magnetic
1
tape
Travel direction: positive
2
6
counting direction
Direction of outgoing cable
3
Admissible deviation of
4
tape/sensor 0.1 ... 2 mm
Maximum alignment error
5
Admissable deviation mid-
6
dle of tape/sensor ±2 mm
PE-connection (cable shoe
7
for M3 only with sensor
cable length >0.3 m)
English
Fig.