Herunterladen Inhalt Inhalt Diese Seite drucken

Programming The User Parameters - Siko MA508 Montageanleitung

Vorschau ausblenden Andere Handbücher für MA508:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MA508

Programming the user parameters

Operating
Actuation
mode
time
ERROR state
<1 sec.
>2 sec.
6 Programming the user parameters
These values are not identical with the "PowerOn" default values.
NOTICE
While the LC display is off, the programmed parameters remain valid. How-
NOTICE
ever, if the voltage supply to the battery is interrupted, all parameters will
be reset to the "PowerOn" defaults.
The electronic display is programmed by means of a hand device avail-
able from SIKO as an accessory called "PTM". for programming, the pro-
gramming plug must be plugged into the ports through the opening on
the rear side of the MA508. In order to ensure electrical contact, the plug
should be slightly bent. After configuring the parameters in the "PTM" as
desired (see User information "PTM"), they can be transmitted to the elec-
tronic display. Following successful transmission, the position value of the
MA508 is at "0" and the device is in the operating mode "Absolute mea-
sure". After programming, the offset value = 0, and the calibration point
deleted.
Display MA508 is pre-programmed to standard values at the factory.
Summary of the pre-programmed standard values
Parameter
LC-Display mode
resolution
decimal point
counting direction positive
reset delay
MA508 · Date 23.05.2017 · Art. No. 83093 · Mod. status 304/16
Key
Switch LCD on/
off (depending on
parameter LC-Dis-
play Mode
Value
Display switches off and is reactived either by a sen-
sor movement or by pressing key
0.1 mm
0.0
off
Key
Key
no function
Calibrate if Reset
Delay OFF
calibrate
English
31
.