The Setup menu

General

The Setup menu makes it easy to adapt the parameters saved in the device to the diffe-
rent types of task:
-
-
-

Gas Setup

Parameters for plasma gas supply
GPr
Gas pre-flow time
Unit
Setting range
Factory setting
GPo
Gas post-flow time
Unit
Setting range
Factory setting
GPU
Gas purger
Unit
Setting range
Factory setting
The plasma gas supply parameters are set in the Gas Setup.
The Setup menu contains parameters which have an immediate effect on the
plasma process.
Machine pre-sets are defined in the Setup menu level 2 (2nd).
+
To enter Gas Setup, press the Store button and the Gas
1
Test button simultaneously.
The plasma gas setting parameter last called is displayed.
Select parameter by pressing the Gas Test button
2
Change the parameter values by using the adjusting dial
3
Press the Store button to exit Gas Setup
4
s
0 - 9.9
0.4
s
0 - 9.9
5
min
OFF / 0.1 - 10.0
OFF
79