5.2. Connecting the light

● Guide the light lines through the installation opening J (connection area for
230 V / 400 V K) into the housing lower part 1 and connect according to the
circuit diagram (Fig. 6) to the terminal k (as described in subsections in 3).

5.3. Connecting the fan (optional)

● Guide the fan lines through the installation openings J (connection area
for 230 V / 400 V K) into the housing lower part 1 and connect to the termi-
nal m according to the circuit diagram (Fig. 6).

5.4. Connecting the optional power booster

● Guide the line for the connection to terminals ST1, ST2, ST3 of the power
booster through installation opening J (connection area for 230 V / 400 V K)
into the housing lower part 1 and connect according to the installation in-
structions of the power booster.

5.5. Connecting heater sensor F1

1. Guide the wires for the heater sensor through the cable bushing 9 into the
low-voltage connection area 5.
2. Connect the red wires for the heater sensor to the terminals labelled "r-r"
in terminal strip 4.
3. Connect the white wires for the heater sensor to the terminals labelled "w-w"
in terminal strip 4.

5.6. Connecting bench sensor F2

1. Feed the wires for the bench sensor through the cable gland 7 into the
low-voltage connection area 5.
2. Connect the wires for the bench sensor to the terminals labelled "w-w" in
terminal strip 4.