4.3. Installing the heater sensor F1 with overheat cut-out
Note Fig. 4 (figures chapter)
● The heater sensor must be installed on the rear of the heater, above the
middle of the sauna heater. A clearance of approx. 15 cm from the ceiling of
the sauna room must be maintained.
● The heater sensor must be attached in a way that it is not affected by a flow
of air.
1. Lay the two 2-pin heater sensor wires in the wall of the sauna room, leading
them to the heater sensor installation location and affix the heater sensor
wires using wire clips.
2. Pull the two half-shells 1 of the heater sensor apart.
3. Connect the four connectors for the heater sensor wire 5 in accordance
with Fig. 4.
4. Place the connection panel 2 crossways in the heater sensor half-shells.
5. Place the two half-shells together, screw them together using the two Phil-
lips-head screws 3 (9 mm) and check whether the heater sensor has been
securely closed.
6. Install the heater sensor on the rear of the heater using the two wood screws
enclosed 6 (16 mm).
p. 11/34