2. Safety instructions

Mechanical installation
DANGER
Electric shock
Death or serious personal injury
In case of an insulation fault, the fault
current may be a DC or pulsating DC.
Observe national legislation about
requirements for and selection of
Residual Current Device (RCD) when
installing the product.
WARNING
Electric shock
Death or serious personal injury
Switch off the power supply before you
start any work on the product. Make
sure that the power supply cannot be
switched on accidentally.
WARNING
Hot liquid
Death or serious personal injury
To avoid leakage do not overtighten
the pipe connections.
CAUTION
Sharp element
Minor or moderate personal injury
Wear personal protective equipment.
CAUTION
Crushing of feet
Minor or moderate personal injury
Wear safety shoes when moving the
product.
Use lifting equipment.
CAUTION
Back injury
Minor or moderate personal injury
Use lifting equipment.
Electrical connection
DANGER
Electric shock
Death or serious personal injury
In case of an insulation fault, the fault
current may be a DC or pulsating
DC.Observe national legislation about
requirements for and selection of
Residual Current Device (RCD) when
installing the product.
6
WARNING
Electric shock
Death or serious personal injury
Carry out the electrical connection in
accordance with local regulations.
WARNING
Electric shock
Death or serious personal injury
Check that the power plug delivered
with the product is in compliance with
local regulations.
The protective earth of the power outlet
must be connected to the protective
earth of the product. The plug must
therefore have the same PE
connection system as the power outlet.
If not, use a suitable adapter if allowed
by local regulations.
Provide protection against indirect
contact in accordance with local
regulations.
Make sure all earth connections are
established correctly before switching
on the power supply.
The user or the installer is responsible
for correct earthing and protection
according to local regulations.
The installer is responsible for potential
compensation.
Work must be carried out according
to IEC 60204-1:2016.
WARNING
Electric shock
Death or serious personal injury
A supply disconnecting device made
according to EN 60204-1 5.3.2 must be
provided with means permitting it to be
locked in the OFF (isolated) position.
This device must also be installed in a
position according to EN 60204-1,
5.3.4.
WARNING
Electric shock
Death or serious personal injury
Power cables without a plug must be
connected to a supply disconnecting
device incorporated in the fixed wiring
according to local regulations.
Cable requirements