2. Press the red release button on the
quick-connect adapter (11) and push
the quick connect adapter (11) onto
the angle adapter (10).
3. Let go of the red release button again.
4. Screw the hose adapter (9) onto the
quick-connect adapter (11).
To screw-on the adaptor:
1. Screw the quick-connect adapter (11)
onto the pump outlet (4).
2. Press the red release button on the
quick-connect adapter (11) and slide
the angle adapter (10) into the quick-
connect adapter (11).
3. Let go of the red release button again.
4. Screw the hose adapter (9) onto the
angle adapter (10).
Fitting height adjustment for
fl oat switch:
Slide the fl oat switch height adjustment
(6) over the fl oat switch guide (8) next
to the handle (1).
Connection of the
pressure line
The installation of the submersible water
pump is implemented either
- with fi xed pipe or
- with fl exible hose line.
If using a ½" hose, attach the hose
over the pump's hose connection (9)
and fasten it with a hose clamp if nec-
essary.
To use a ¾", 1" or 1½" hose, cut off
the connection above and attach the
hose over the correct connection (fi xing
with a hose clamp).
For the use of a tap connector with
internal thread (G 1") for connecting
external hose connection systems, cut
the top three connections off directly
over the G 1" threaded pipe.
Connect a tap connector with internal
thread (G 1 ½") directly to the angle
adapter (10).
• Connect a tap connector with internal
thread (G 1 ½") directly to the quick-
connect adapter (11).
Measurement of the maximum perfor-
mance data is done under optimal
conditions, such as a straight, direct exit. The
angle adapter (10) can reduce the output.

To erect/suspend

The pump can be erected or sus-
pended in the water.
The cord (12) contained in the
delivery contents may be used to
suspend and/or extract the pump.
The pump shaft should have the dimen-
sions 40 x 40 x 50 cm at least, so that the
fl oat switch can move freely.
Fix the nylon rope (12) onto the carrying
handle (1).
Ensure that the equipment is
not hung up or held by the
mains cable. There is a risk
of electric shock from dam-
aged mains cables.
Note that, over time, dirt and sand
may collect on the bottom of the
shaft, which could damage the
pump.
We recommend placing the pump
on a brick or a grid.
If the water level is too low, the silt
in the shaft can quickly dry out and
impede the pump when warming
up.