Check the fl oat switch (5).
- It must be positioned so that it
can lift and lower freely. The
switching point heights "On" and
"Off" must be easy to reach.
Check this by placing the pump
into a vessel fi lled with water
and lift the fl oat switch (5) care-
fully by hand and then lower it
again. In this case, you can see
whether the pump switches on
and off.
- Make sure that the distance
between the fl oat switch (5) and
the fl oat switch height adjust-
ment (6) is not too short. If the
distance is too short, the device
may not work properly.
- During the adjustment of the fl oat
switch (5), ensure that the fl oat
switch does not contact the fl oor
before the pump switches off.
There is a risk of dry running if
the fl oat switch cable (7) is set too
long, especially if the fl oat switch
height adjustment (6) is not fi tted
(see "Start up").
Manual mode/fl at
suction
Caution: Avoid dry running
of the pump! Danger of over-
heating!
Never touch an overheated
pump! There is a danger of
burns!
In manual mode, the pump does not switch
off automatically, as the fl oat switch (5) is
bypassed.
The fl oat switch (5) must be positioned ver-
tically upwards on the pump for this.
Slide the fl oat switch height adjustment (6)
over the fl oat switch guide (8) next to the
handle (1).
Pull the fl oat switch cable (7) through the
fl oat switch height adjustment (6), until
the fl oat switch (5) is positioned vertically
above the height adjustment (6). See illus-
tration
.
Monitor the pump constantly when
in manual mode. Switch the pump
off immediately (disconnect from the
mains) if no more water is being
pumped. There is a risk of damage
if the pump runs dry.
Maintenance and
Cleaning
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to car-
ry out any work that is not
described in these instruc-
tions. Use only original parts.
There is a risk of injury!
Pull out the power plug before
every maintenance operation. There
is a risk of electrocution or of injury
from moving parts.
General cleaning
instructions
In case of transport for utilization in
different locations, the pump must be
cleaned with clear water after every
use.
In case of stationary installation, the
function of the fl oat switch (5) is to be
checked regularly (at the latest every
three months).