R911174196 | PSI 6xCx.766xx
Tab.7: Discrete outputs
Bits
Outputs
A_0
Reserved
A_1
Close weld contactor
A_2
Link from serial input 1.4
A_3
UI Regulation active
A_4
UI monitoring active
A_5
Q Stop
A_6
Free
A_7
Free
A_8
Free
A_9
Free
A_10
Free
A_11
Reserved
A_12
Free
A_13
Reserved
A_14
Reserved
A_15
Reserved
A_16
Free
A_17
Free
A_18
Free
6.3
Other inputs/outputs
Tab.8: Other inputs
Inputs
Secondary current
Secondary voltage
Digital pressure feedback
Analog force input
Transformer temperature
Tab.9: Other outputs
Outputs
Analog pressure output
Fan
"Operate" force sensor
Bosch Rexroth AG
43/60
Input/Output array