Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

9.4. EVCO thermostat

Fig. 17 EVCO thermostat panel
LEDs ON THE DISPLAY
LED 1 - Compressor: the LED is on when the compressor is running. It blinks when the temperature settings are being
changed; compressor delay time resulting from parameters C0, C1, C2 and i7
LED 2 - Fan: the LED is on when the evaporator fans are on. The symbol blinks when the fan start is delayed after dripping
(parameter F3)
LED 3 - Defrosting: the LED is on when the defrosting function is activated. It blinks when the defrosting is required, but
the compressor delayed is activated (parameter C0, C1 and C2), when the dripping is in progress (parameter d7), or the
coolant heating is in progress (parameter dA)
LED 4 - Alarm: the symbol is visible when an alarm is active
LEDs 5 – current temperature inside the equipment (with one decimal place)
SET DESIRED TEMPERATURE
Keypad lock/unlock
Lock:
Simultaneously press
Unlock:
Simultaneously press
Change temperature settings:
Make sure the keypad is unlocked and no procedure is active
Press
, LED
Use
or
Confirm by pressing
MANUAL DEFROSTING
Defrosting is performed automatically. However, you can start it manually anytime.
Make sure the keypad is unlocked and no procedure is active
Press
for minimum 4 seconds.
*More on www.berling.pl/pl/asortyment/evco
24
Instruction manual - cooling and freezing devices
i
for 2 second. The display will show "Loc"
i
for 2 second. The display will show "Unl"
will start blinking
to change the setting (remember the limitations r1, r2 and r3)