Incorrect temperature*
Lighting does not
work
Dew on internal com-
ponents
Water leaks from
under the equipment
or to the chamber
Excessively nosy
operation
* During the defrosting the indications on the thermostat display and on the thermometer may differ significantly, as the current temperature on the display may be
"blocked" for the duration of defrosting. If you are not sure of the equipment is defrosting, wait 1-1.5 hours and recheck the temperature. If the temperatures do not
change, the equipment might have failed. If you cannot determine the cause, switch off the equipment, disconnect it from the mains, and call authorized service.
IGLOO.PL
Main switch on the control panel is OFF
Temperature on thermostat – the wrong
range is set
Ambient temperature higher than 25ºC
Equipment placed not according to the instal-
lation guidelines
A sufficient time has passed for refrigeration
of products
Thermostat failure
Dirty condenser and/or condenser filter
Blocked ventilation openings
Light switch is OFF
Damaged lighting system
Incorrect operating conditions. Humidity is
too high
Blocked ventilation openings
Equipment is not levelled well
Obstructed outflow pipes, blocked sewers
Overfilled condensate container
Iced evaporator and evaporator trough
Refrigeration system failure
Equipment not stable and is not levelled
properly
Internal parts incorrectly placed and fastened
Put the main switch to ON and check if
the thermostat is working
Set the correct temperature range
Ensure the correct temperature and
operating conditions
Correct the place of installation and/or
operating conditions (section 5.1)
Wait about 20 minutes and check if
temperature has changed
Call authorized service
Clean
Uncover ventilation openings inside
the equipment; uncover condenser
ventilation openings
Put the light switch to ON
Replaced the LED light
Ensure the correct operating conditions
Unblock air inlets and outlets
Level the equipment
Ensure unobstructed flow through
outflow pipes and sewers
Empty the condensate container or the
evaporator overflow container
Defrost – (Section X)
Check the suggested solution given
above. If the problem persists, call
authorized service
Put the equipment on straight, stable
surface and level it correctly
Fasten the internal parts correctly
Instruction manual - cooling and freezing devices