ALARMS on DIXELL
thermostat panel
18
Instruction manual - cooling and freezing devices
P1 – temperature sensor error inside the
chamber
P2 – evaporator sensor error
P3 – condenser sensor error (if any)
HA2 – high condenser temperature
LA2 – low condenser temperature
dA – open door alarm
EA – external alarm
CA – serious alarm
rtc – real time clock alarm
rtF – real time clock error
LA – low temperature alarm (lower than set
temperature range inside the equipment)
AL and HA – These alarms can be caused
by incorrect mains parameters, or incorrect
placement of products inside the equipment.
HA – high temperature alarm
LA and HA – These alarms can be caused
by incorrect mains parameters, or incorrect
placement of products inside the equipment.
Call authorized service
Call authorized service
Call authorized service
Clean the condenser (procedure in the
Manual). If the alarm reoccurs after
restarting the equipment, call authorized
service.
Turn off the equipment using the main
switch, turn it on again after a while. If
the problem reoccurs, call authorized
service
The alarm is deactivated after closing
the door. If the alarm is displayed when
the door is closed, call authorized
service.
The alarm is of after deactivation of
the digital input (depending on input
configuration)
Deactivation of all inputs. Call authori-
zed service
The alarm will disappear when the
clock is set
Call authorized service
Check if the products do not cover or to-
uch the temperature sensors, or do not
cover air circulation openings. Place the
product correctly and wait for 1 h. The
alarm will disappear when the tempe-
ratures return to normal values. Reset
the alarm by turning the equipment off
using the main switch. If the problem
reoccurs (alarm is displayed again), call
authorized service!
en
IGLOO.PL