During the first start of equipment with an air-trap pour about 0.3 litres of water to each outflow opening in order
to fill the air-trap. Air-traps filled with water are natural valves preventing entry of unpleasant smell from sewers.

5.2.4.Connecting to sewers (REMOTE type)

If the equipment features an external unit (mod/C), connect the defrosting water drainage directly to sanitary
sewers and carefully inspect the pipes and fastenings, check the unobstructed flow and leak-tightness. The
pipes connection places are marked in

5.2.5.Connecting to mains

Start the equipment only after verifying the effectiveness of electric shock protection by means of measu-
rements conforming to applicable regulations!
IGLOO.PL
Fig.2 Typical condensate container
1 – Water drain from the equipment (air-trapped)
2 – Water drain hose from trough (outflow of condensa-
te from evaporator defrosting)
3 – Condensate container (to be emptied)
Fig.3 Typical overflow (version with evaporating tank)
1 - Water drain from the equipment (air-trapped)
2 - Water drain hose from trough (outflow of condensate from evapo-
rator defrosting)
3 - Overflow (remove condensate if water overflows from evapora-
ting tank!)
4 – Evaporating tank
Fig. 4 Typical condensate tray
1 – Water (condensate) drain hose
2 – Condensate tray
Fig. 5 Typical condensate container (outflow without
air-trap)
1 – Ventilation openings
2 – Condensate container
3 – Water drain hose
.
Instruction manual - cooling and freezing devices
en
11