Herunterladen Inhalt Inhalt Diese Seite drucken

Information On The Installation Of The Lock; Installation Of The Lock; Cable Layout - effeff 809 Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.3

Information on the Installation of the Lock

Mounting and electrical connection must be carried out by a qualified technician!

2.3.1 Installation of the Lock

Preparation of the door leaf, such as drilling, milling or similar, must never be carried out
after the lock has been mounted or inserted into the lock pocket.
The recess of the lock pocket must be prepared in accordance with the dimensions below. It
must be possible to insert the lock into the lock pocket without expenditure of force to fix it to
the door leaf without strain by using the bore holes in the faceplate.
The depth of the recess for the lock pocket is calculated by the depth of the lock case plus
an addition of about 30 mm for a cable loop (revision!). Please pay especially attention to the
dimensions of the coupler plug! In case of profiles for tubular frames the loop of the connec-
ting cable can be jammed in a fitting profile chamber if necessary.

2.3.2 Cable Layout

The connecting cable of the effeff security lock 809 must be laid in the door leaf from the
lock side to the hinge side, if possible in a conduit with an inner diameter of at least 7 mm.
Any loops should be as large as possible.
If a conduit cannot be fitted, e.g. because the lock is mounted later in an existing
door, the cable must be laid particularly carefully.
Edges must be rounded off to prevent damage to the cable covering.
From the door leaf to the frame the cable must be laid in a flexible bridging cable
which is firmly fixed to the door leaf and the frame, e.g. effeff model 10318 or
10312. Please observe the respective mounting instructions in this regard.