Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
If the pipe cross-section is smaller or the length greater, the functions of the consumer device
are no longer guaranteed. Check the supply pressure p
(≥ 42.5 mbar) upstream from the connected device.

CONNECTIONS

Inlet, optional
Other connections
22 / 182
Trading name and dimensions
acc. to standard
Italian connection (Ital.A)
• with rubber gasket and cap nut
• G.1 = Thread W 20 x 1/14 ÜM
Large cylinder connection (GF)
• with aluminium gasket
• G.4 = Thread W 21.8 x 1/14 lh
Combinded fitting (Komb.A)
• with polyamide gasket
• G.5 = Thread W 21.8 x 1/14
US POL connection
• with sealing fitting and retaining screw
• G.9 = Thread 0.880-14 NGO lh
POL connection, soft
• with rubber gasket and retaining screw
• G.10 = Thread 0.880-14 NGO lh
Small cylinder KLF (KLF)
• with 5-wing cap nut
• G.12 = Thread W 21.8 x 1/14 ÜM
Compression fitting
• G.22 = compr. fit 12, 15, 18, 22, 28 or 35
Cylindrical female thread
• G.37 = F G 1/4, G 3/8, G 1/2, G 3/4 or G 1
• For a screw-in connector with O-ring
Emergency supply connector with non-return
valve
• Thread G 3/8 lh M
Test connector
• 9 mm nozzle
• with set screw
Behälterregler-Kombination PS 25 bar
according to EN 16129 Table 5
min
Installation notes
Spanner size 25
Hexagonal
Spanner size 30
Hexagonal
Spanner size 30
Hexagonal
Spanner size 24
Hexagonal
Spanner size 24
Hexagonal
Tighten hand-tight.
Installation notes
See emergency
supply connector
option
Loosen the set
screw with a
screwdriver, attach
the test hose.
Artikel-Nr. 05 288 50 m

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bhk 052 upsoBhk 052bBhk/k

Inhaltsverzeichnis