sieve insert (12.1) on the water connec-
tion (13) of the device.
2. Hang the end with the fi lter basket into
the water collector (e.g. rain barrel).
Ensure there is a suffi cient and reliable
water supply.
Dry running will damage the de-
vice.
3. Remove the lance (3) from the spray
gun (14). Press the switch-on lever (19)
on the spray gun (14) and then turn the
device on.
4. The device begins to suction water and
air can escape.
5. Once the device is free of air, you can
release the switch-on lever (19) on the
spray gun (14). You can connect an
attachment of your choice to the spray
gun (14).
The device should not be higher
than the tap point.
Cleaning and

Maintenance

Pull out the power plug before eve-
ry maintenance operation. This also
includes connecting to the water
supply or trying to eliminate leaks.
There is a risk of electrocution or of
injury from moving parts.

Cleaning

Never direct the water jet
against the pressure cleaner,
nor clean the pressure clean-
er under fl owing water. This
could give rise to the danger
of electric shock and damage
the pressure cleaner!
Always keep the pressure cleaner
clean. Do not use any detergents or
solvents.
28
• Always keep the ventilation slots clean
and free.
• Only clean the pressure cleaner with a
soft brush or a slightly moist cloth.
• If the standard Vario nozzle (25) is
soiled or blocked, you can remove any
foreign bodies in the nozzle using the
nozzle cleaning needle (30). Rinse the
standard Vario nozzle with water to
remove the foreign body.
• Clean the sieve insert (12.1) under run-
ning water.
Maintenance
The pressure cleaner is maintenance free.
Ask our service centre to car-
ry out any work that is not
described in these instruc-
tions. Use only original parts.

Storage

• Drain all the water from the pressure
cleaner.
Disconnect the unit from the water sup-
ply. Press the On/Off switch (8) to turn
on the pressure cleaner for no longer
than 1 minute until no more water es-
capes from the jet gun(14) or from the
attaching parts (21/25/26). Turn off
the unit.
• Store all add-ons (21/25/26) vertically
with the connection side facing down-
wards.
• Protect the pressure cleaner and its ac-
cessories from frost when they have not
been completely drained of all water.
• Store the pressure cleaner and its ac-
cessories in a frost-free room.
• Roll the high-pressure hose (4) onto the
hose reel (5) and secure it using the
Velcro fastener on the high-pressure
hose (4.2).
• Store the cord (10) in the holder (9)
provided. Use the clip for the cord