Herunterladen Inhalt Inhalt Diese Seite drucken

GF UD2100 Betriebsanleitung Seite 46

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

UD2100 Ultrasonic Doppler Flow Meter
Register Address
Description
30318
Previous day Volume
Total - Gallons
30319
Previous day Volume
Total - Liters
30320
Previous day Volume
Total - Liters
30321
Previous day Volume
Total - ft3
30322
Previous day Volume
Total - ft3
30323
Previous day Volume
Total - m3
30324
Previous day Volume
Total - m3
30325
Previous day Volume
Total - USMG
30326
Previous day Volume
Total - USMG
30327
Previous day Volume
Total - IG
30328
Previous day Volume
Total - IG
30329
Previous day Volume
Total - IMG
30330
Previous day Volume
Total - IMG
30331
Previous day Volume
Total - bbl
30332
Previous day Volume
Total - bbl
30901
Signal Strength - %
30904
Run Hours
30905
Run Hours
30923
Sensor Status
30925
Logging Status
30926
Logging Used - %
30927
Logging Used - %
30962
Confidence
30963
Direction
30964
Pot 1
30965
Peak to Peak
30966
Correlation Strength
46
Register Type
Format Type
Input Register Floating Point Register (2 of 2)
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Integer
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Index (0-10)
Input Register Index (0-2)
Input Register Floating Point Register (1 of 2)
Input Register Floating Point Register (2 of 2)
Input Register Integer
Input Register Integer
Input Register Integer
Input Register Integer
Input Register Integer
Operating Instructions
Comments
USMG = US Million Gallons
USMG = US Million Gallons
IG = Imperial Gallons
IG = Imperial Gallons
IMG = Imperial Million Gallons
IMG = Imperial Million Gallons
bbl = US Oil Barrel = 42 Gallons
bbl = US Oil Barrel = 42 Gallons
0-100
0 = Sensor Good
4 = Sensor Open
5 = Sensor Short
7 = Low Signal
0 = Stopped
1 = Active
2 = Full