GF UD2100 Betriebsanleitung Seite 23

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Instructions
-- Special Functions--------
Language
Analog Out
Backlight
Reset Totalizer
Neg. Totals
Rev. Flow
CapturePar
CaptureWF
RestoreDefaults
New Password
Communication (Optional) cont.
BPS (Modbus)
Baud rate for the MODBUS communications. Press
ting. Options: 4800, 9600, 19200, 38400, 57600, 76800, and 115200 (Default: 9600).
Parity (Modbus)
Error checking parity for the MODBUS communications. Press
store the setting. Options: None, Even, and Odd (Default: Even).
Stop Bits (Modbus)
Press
or
Special Functions
English
4-20mA
Language
High
No
Select English, French or Spanish.
No
No
Analog Out
No
No
Select 4-20mA or 0-5V mode for the analog
No
output.
0000
Backlight
Select High, Medium or Low for continuous backlight.
Select Key Hi/Lo for high backlight for 1 minute after a keypress and then Lo backlight until
a key is pressed again.
Select Key High, Med or Low for backlight for 1 minute after a keypress and then backlight off
until a key is pressed again.
Reset Totalizer
Press
and select Yes to erase and restart the totalizer at zero.
Neg. Totals
Select Yes to have reverse flow readings deducted from the totalizer. Select No to totalize
forward flow only and ignore reverse flow.
Rev. Flo
Select On to enable flow direction measurement. Select Off to disable flow direction mea-
surement. Select Invert to invert the sense of the flow measurement.
Capture Par
This function captures the programming parameters in the meter. Select Yes, wait for
Insrt USB to appear, then insert a USB drive into the USB port to transfer the parameters.
After Saving flashes, Done will appear on the screen, meaning it is safe to remove the USB.
to select, and
to store the setting. Options: 1 or 2 (Default: 1).
UD2100 Ultrasonic Doppler Flow Meter
or
to select, and  to store the set-
or
to select, and  to
23