Betriebsanleitung
Termination: Jumper Position
Function Codes Supported:
01 – Read Coil(s)
02 – Read Discreet Input(s)
04 – Read Input Register(s)
05 – Write Single Coil
06 – Write Single Register
15 – Write Multiple Coils
16 – Write Multiple Registers
17 – Report Slave ID
9.2

Modbus Memory RAM

Register Address
Description
1
Reset
Volume
Total
Register Address
Description
10001
Pulse
Output 1
Status
10002
Pulse
Output 2
Status
Register
Data
Over
Type
Range
Range
Coil
NA
NA
Register
Data
Over
Type
Range
Range
Discreet
NA
NA
Input
Discreet
NA
NA
Input
UD2100 Ultraschall Doppler Durchflussmessgerät
Read/
Comments
Write
Read/
Turn coil ON (1) to reset total on GF UD2100. Turn
Write
coil to OFF (0) once reset is complete.
Read/
Comments
Write
Read
(0) indicates pulse output is OFF or inactive.
(1) indicates pulse output is ON or active.
Read
(0) indicates pulse output is OFF or inactive.
(1) indicates pulse output is ON or active.